Price range: Update. The probe transmits readings digitally to the meter, where data points can be displayed and logged. Fax: +1 800-468-8921. The HI98194 is a waterproof portable logging multiparameter water meter that monitors up to 12 different water quality parameters. . The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert. The complete system is simple to setup and easy to use. Please exclude HTML, as this may cause your question to be blocked. Benzene-Specific Photoionization Detectors, J.U.M. Comes as a complete system, allowing you to start taking measurements as soon as you receive it. 4851 Sunrise Drive, Suite 101, Martinez, - The display of the meter has a battery icon indicator to show the remaining power. Please enter feedback to submit (no html or links). The HI98194 is a waterproof portable logging multiparameter water meter that monitors up to 12 different water quality parameters. The probe features an IP68 rating for continuous immersion in water. Forestry Suppliers reserves the right to post any question that we feel might benefit other customers or enhance understanding of the product. Water Quality Test Kit - Accurate and Reliable Water Quality Tests New COMPANY: HANNA ROMANIA. The interface is intuitive for any users level of experience. Contextual help is always available through a dedicated HELP key. The HI98194 is a waterproof portable logging multiparameter meter that monitors up to 12 different water quality parameters including 6 measured and 6 calculated. - The display of the meter has a battery icon indicator to show the remaining power. Promo khusus pengguna baru di aplikasi Tokopedia! The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, conductivity, and dissolved oxygen. Ports on the probe accommodate color-coded, field-replaceable sensors. HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert. Standard pH calibration options are available for calibrating up to three points from a selection of five standard buffers and one custom buffer. please contact your local Hanna Instruments Office. Multiparameter Meter merupakan kombinasi canggih Electro teknologi sensor dengan keadaan elektronik dan desain perangkat lunak. The graphic display allows for the use of virtual keys to provide for an intuitive user interface. At present, most of the water quality monitoring instruments are independent instruments, such as turbidity meter, pH meter, conductivity meter, dissolved oxygen meter, etc. Product was successfully added to your shopping cart. Weight: 14.2 oz. - The HI7698194 probe features a Quick Connect DIN connector that makes a waterproof connection with the meter. The HI98194 is a waterproof portable logging multiparameter water quality meter that monitors up to 12 different parameters. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. A backlit, graphic LCD provides easy to read resolution even in low-lit areas. GLP Data -HI98194 includes a GLP feature thatallows users to view calibration data and expiration information at the touch of a key. Backlit Graphic LCD Display The HI98194 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. Waterproof Protection - The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1m for up to 30 minutes. Meter - HI98194 di ToserLab. Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. Conductivity calibration is a single point from six standard selections or one custom standard. Rinse sensor with water. HI98194 Instructions manual Hanna Instruments HI98194 Instructions Manual Multiparameter meters ph/mv, orp, ec, tds, resistivity, salinity, seawater, dissolved oxygen, atmospheric pressure and temperature Also See for HI98194: Instruction manual (37 pages) 1 2 Table Of Contents 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 The meter uses four 1.5V AA batteries that provide up to 360 hours of battery life. Please, provide as much detail as possible to help expedite your request. The help information displayed is relative to the setting/option being viewed. automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer, automatic at one custom point (relative mV), 0 to 200 mS/cm (absolute EC up to 400 mS/cm), auto-ranging: 1 S/cm from 0 to 9999 S/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 S/cm; 0.001 mS/cm; 0.01, 1% of reading or 1 S/cm whichever is greater, automatic single point, with six standard solutions (84 S/cm, 1413 S/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point, 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor). Then we want to hear from you! Quick Connect Digital Probe - The HI7698194 probe features a Quick Connect DIN connector that makes a waterproof connection with the meter. A total of 247 uniformly distributed frames from the video footage were manually annotated to train a YOLOv4 model for fish recognition and tracking. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The interface is intuitive for any users level of experience. Long BatteryLife - The display of the water quality meter has a battery icon indicator to show the remaining power. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. What is a Photoionization Detector (PID)? Dedicated Help Key-Contextual help is always available through a dedicated HELP key. - The HI98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The HI7698194 is a multiparameter pH/EC/DO/Temperature probe for use with the HI98194 portable meter. The interface is intuitive for any users level of experience. The complete system is simple to setup. Items marked with a red asterisk (*) are required. Setup screenOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides. Dimensions: 7.3 x 3.6 x 1.4. Multi-Parameter Meters. pH With operations in 65 Countries, Hanna is working to solve some of the world's biggest problems by making scientific testing more accessible, easy, and accurate. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The Ultimate Sampling Handheld. - The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation. The HI98194 is a waterproof portable logging multiparameter water meter that monitors up to 12 different water quality parameters. We encourage our customers to let us know what experiences they have had with our products, whether good or bad. In addition to auto-sensor recognition, the meter features automatic temperature compensation, automatic logging for up to 45,000 samples, and log-on-demand to store data at the press of a button. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. HI-98194 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. HI98194 MULTIPARAMETER PORTABLE WATERPROOF WITH HI7698194 PROBE,HI7698194-1,HI7698194-3,HI769 8194 PH/ORP/EC/DO SENSOR,HI76981942 PROBE MAINTENANCE KIT,HI7042S,HI9298194 HANNA PC SOFTWARE; SPECIFICATIONS 3.1. Jual Hanna HI98194 Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature harga murah 2023 di Kucari.com - Garansi Pembayaran aman Pengiriman cepat Bisa PPN Tentang Kucari.com Tentang Kami Hubungi Kami Pelanggan Kami Testimoni Pelanggan Blog Daftar Bisnis+ Anda Supplier? Multiparameter water quality meters incorporate multiple sensors into a single large "probe," commonly referred to as a sonde. Cable length 4m. Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides. Color Coded, Field Replaceable Sensors Sensor replacement is quick and easy with field replaceable, screw type connectors that are color coded for easy sensor port identification. Visit EnviroTech Online for environmental monitoring equipment. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. Any ports not used on the probe will not have the parameter displayed or be configurable. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. Waterproof Protection - The multiparametermeter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1m for up to 30 minutes. Quick CalibrationThe quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in a few simple steps. Volatile Organic Compounds Detected by PIDs. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics. Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. 109L Non-Methane Hydrocarbon Analyzer, Benzene-Specific Photo Ionization Detectors, CALIBRATION GASES, SOLUTIONS & ACCESSORIES, How FEI is handling the COVID-19 Pandemic. manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt): 1% of reading or 1 ppm (mg/L), whichever is greater, based on conductivity or salinity calibration, 0 to 999999 cm; 0 to 1000.0 kcm; 0 to 1.0000 Mcm, 2% of reading or 0.01 PSU whichever is greater, 0.0 to 300.0% saturation: 1.5% of reading or 1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): 1.5% of reading or 0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): 3% of reading, 300.0 to 500.0% saturation: 3% of reading, automatic one or two points at 0 and 100% or one custom point, 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa, 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa, 3 mm Hg within 15C from the temperature during calibration, -5.00 to 55.00 C, 23.00 to 131.00 F, 268.15 to 328.15 K, automatic from -5 to 55 C (23 to 131 F), 45,000 records (continuous logging or log-on-demand of all parameters), USB to PC with HI9298194 Hanna software installed, 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight). - The HI98194 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. We have rentals from soil sampling, water quality Instruments, and air testing supplies. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The HI7698194 is a multiparameter pH/EC/DO/Temperature probe for use with the HI98194 portable meter. - The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1m for up to 30 minutes. The HI98194 is a waterproof portable logging multiparameter meter that monitors up to 12 different water quality parameters including 6 measured and 6 calculated. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. This meter measures pH,. Windows 10 & below. The HI98194 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Choose a conductivity meter to monitor the amount of nutrients, salts or impurities in the water. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components. The complete system is simple to setup. Any ports not used on the probe will not have the parameter displayed or be configurable. HANNA HI2550 pH/ ORP/ ISE/ EC/ TDS/ NaCl Benchtop Meter. The multiparameter probe transmits readings digitally to the meter, where data points can be displayed and logged. manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt): 1% of reading or 1 ppm (mg/L), whichever is greater, based on conductivity or salinity calibration, 0 to 999999 cm; 0 to 1000.0 kcm; 0 to 1.0000 Mcm, 2% of reading or 0.01 PSU whichever is greater, 0.0 to 300.0% saturation: 1.5% of reading or 1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): 1.5% of reading or 0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): 3% of reading, 300.0 to 500.0% saturation: 3% of reading, automatic one or two points at 0 and 100% or one custom point, 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa, 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa, 3 mm Hg within 15C from the temperature during calibration, -5.00 to 55.00 C, 23.00 to 131.00 F, 268.15 to 328.15 K, automatic from -5 to 55 C (23 to 131 F), 45,000 records (continuous logging or log-on-demand of all parameters), USB to PC with HI9298194 Hanna software installed, 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight). manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt): 1% of reading or 1 ppm (mg/L), whichever is greater, based on conductivity or salinity calibration, 0 to 999999 cm; 0 to 1000.0 kcm; 0 to 1.0000 Mcm, 2% of reading or 0.01 PSU whichever is greater, 0.0 to 300.0% saturation: 1.5% of reading or 1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): 1.5% of reading or 0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): 3% of reading, 300.0 to 500.0% saturation: 3% of reading, automatic one or two points at 0 and 100% or one custom point, 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa, 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa, 3 mm Hg within 15C from the temperature during calibration, -5.00 to 55.00 C, 23.00 to 131.00 F, 268.15 to 328.15 K, automatic from -5 to 55 C (23 to 131 F), 45,000 records (continuous logging or log-on-demand of all parameters), USB to PC with HI9298194 Hanna software installed, 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight). The meter offers: Measurement of up to 12 different water quality parameters Quick calibration for a speedy calibration for pH, conductivity, and dissolved oxygen using one solution 20 Cal Arc Flash Protection Clothing Kits, 25 Cal Arc Flash Protection Clothing Kits, 40 Cal/CM2 Arc Flash Clothing Kits (HRC 4), 100 Cal Arc Flash Protection Clothing Kits, Single & Three Phase Underground Dead Front Grounding Sets, Standard three phase live front grounding set, Shorting Probes & Capacitive Discharge Tools, Insulated Rubber Glove Kits for Electrical Work, SF6 Analyzers For Gas Insulated Switchgear, Pre-Cut Stainless Steel Alignment Shim Kits & Shims, RCM Flo-Gage Direct Reading Liquid/Gas Flow Meter, pH and Conductivity Standardization Solutions, Pen Style Liquid Testers- TDS and Conductivity, AEMC 8335 Powerpad Three Phase Power Analyzer, AEMC 3945-B Three Phase Power Quality Analyzer, Megger MIT510 MIT520 & MIT1020 Insulation Testers, 3D Accu-Drive Analog Reference Pressure Gauges, Hanna HI98194/40 Multiparameter Temperature Waterproof Meter, Skip to the beginning of the images gallery, automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer, automatic at one custom point (relative mV), 0 to 200 mS/cm (absolute EC up to 400 mS/cm), auto-ranging: 1 S/cm from 0 to 9999 S/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 S/cm; 0.001 mS/cm; 0.01, 1% of reading or 1 S/cm whichever is greater, automatic single point, with six standard solutions (84 S/cm, 1413 S/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point, 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor). The graphic display allows for the use of virtual keys to provide for an intuitive user interface. Masuk Daftar. DOWNLOAD NOW . Dissolved oxygen calibration is up to two standard points or a single custom point. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. Range - pH/mV: 0.00 to 14.00 pH/600.0 mV; ORP: 2000.0 mV; EC: 0 to 200 mS/cm (absolute EC up to 400 mS/cm); TDS: 0.0 to 400.0 ppt (g/L) (maximum value depends on the TDS factor); Resistivity: 0 to 999999 cm, 0 to 1000.0 kcm, 0 to 1.0000 Mcm; Salinity: 0.00 to 70.00 PSU; Seawater Sigma: 0.0 to 50.0 t, 0, 15; DO: 0.0 to 500.0%, 0.00 to 50.00 ppm (mg/L); Atmospheric Pressure: 450 to 850 mm Hg, 17.72 to 33.46 in Hg, 600.0 to 1133.2 mbar, 8.702 to 16.436 psi, 0.5921 to 1.1184 atm, 60.00 to 113.32 kPa; Temperature: -5.00C to 55.00C, 23.00F to 131.00F, 268.15 K to 328.15 K. Accuracy - pH/mV: 0.02 pH/0.5 mV; ORP: 1.0 mV; EC: 1% of reading or 1 S/cm whichever is greater; TDS: 1% of reading or 1 ppm (mg/L), whichever is greater; Salinity: 2% of reading or 0.01 PSU whichever is greater; Seawater Sigma: 1 t, 0, 15; DO: 0.0 to 300.0% saturation: 1.5% of reading or 1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): 1.5% of reading or 0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): 3% of reading, 300.0 to 500.0% saturation: 3% of reading; Atmospheric Pressure: 3 mm Hg within 15C from the temperature during calibration; Temperature: 0.15C; 0.27F; 0.15 K. Logging Memory: 45,000 records (continuous logging or log-on-demand of all parameters). Its rugged, waterproof design makes it ideal for field use. Great for environmental and industrial professionals. Logged data can be transferred to a Windows compatible PC with the included HI920015 micro USB cable and HI9298194 software. The Hanna HI9828 Multiparameter Water Quality Meter is a comprehensive analytical instrument, capable of measuring up to 13 critical water quality parameters (6 measured and 7 calculated) simultaneously including: pH; Electrical Conductivity (EC) Redox (ORP) Dissolved Oxygen (% Saturation) Dissolved Oxygen (mg/L) Absolute Electrical Conductivity

Editorial Article About Sports, Chicken Wants To Come Inside, Articles H